• Home  
  • A novel wireless strain sensing technology based on RF energy harvesting for structural health monitoring
A novel wireless strain sensing technology based on RF energy harvesting for structural health monitoring
- Technology

A novel wireless strain sensing technology based on RF energy harvesting for structural health monitoring

Experimental tests of monitoring distance To investigate the communication performance of the wireless sensing node, experimental tests were conducted to evaluate the monitoring distance and communication effectiveness. Figure 4 shows the RCRD001 ultra-high frequency reader, which serves as the universal RFID transmitter module. The test sensor was positioned within the signal coverage range of the transmitter

Experimental tests of monitoring distance

To investigate the communication performance of the wireless sensing node, experimental tests were conducted to evaluate the monitoring distance and communication effectiveness. Figure 4 shows the RCRD001 ultra-high frequency reader, which serves as the universal RFID transmitter module. The test sensor was positioned within the signal coverage range of the transmitter module, and distance data were recorded as the sensor was gradually moved during testing. The self-developed wireless sensing node utilized dedicated data acquisition and debugging software to transmit monitoring data. To ensure the reproducibility and comparability of the experimental results, all tests were conducted in an indoor corridor environment under unobstructed line-of-sight conditions between the transmitter and the device under test. Both the RFID reader module and the proposed sensing node were mounted on platforms at a height of approximately 1.0 m above the ground. The antennas were co-aligned in both orientation and polarization to minimize mismatch losses. No additional wireless communication devices were intentionally introduced in the vicinity to limit external interference. The sensor was translated linearly within the signal reception range. The output current (mA) was measured using a current meter, and the communication effectiveness was assessed based on data reception performance.

Fig. 4

Details of the monitoring distance testing: (a) the sensing node; (b) the monitoring distance testing; (c) the monitoring data reception.

In this study, a hybrid communication architecture integrating a general RFID transmitter and a LoRa receiver module is adopted. The LoRa receiver is responsible for acquiring RF signals transmitted from the sensing node and converting them into processable digital data. Figure 5(a) shows the receiver operates at a carrier frequency of 490 MHz, enabling wireless data transmission between the sensing node and the host computer. As illustrated in Fig. 5(b), it employs efficient modulation, demodulation, and encoding schemes. The coordinated operation of these components ensures stable and reliable signal reception.

Fig. 5
Fig. 5

Details of the LoRa receiver module.

Figure 6 depicts the evaluation of the measured sensor output current intensity (mA) and the actual communication performance of the sensing node. The results indicate that, within a monitoring distance range of 4.01 m, the output current remains consistently above 0.343 mA, indicating excellent communication effectiveness. At a monitoring distance of 5.01 m, the output current decreased to 0.245 mA, indicating moderate communication performance, accompanied by reduced communication frequency and occasional transmission failures. When the communication distance increased to 9.00 m, the output current further declined to 0.080 mA. Under these conditions, the sampling frequency was significantly reduced, the charging time increased, and data reception became intermittent, indicating poor communication performance. Moreover, when the monitoring distance exceeded 10 m, power supply failures occurred, resulting in insufficient energy to sustain data recognition and transmission, ultimately leading to complete communication failure. Overall, the wireless sensing node achieves stable continuous monitoring and data transmission within approximately 4 m of the RFID transmitter, supporting the transmission of multiple data points simultaneously.

Fig. 6
Fig. 6

The current intensity of the proposed approach.

Experimental validation of strain measurement

To verify the accuracy of the developed wireless strain sensing technology for structural strain measurement, a test platform was built to measure the strain performance of a cantilever beam under loading. As shown in Fig. 7, the testing platform consists of the cantilever beam, an RCRD001 ultra-high-frequency integrated reader, resistance strain sensors, a reader, and a computer. During the bending experiment, the proposed wireless strain sensing syetem acquired strain data from the beam in real time under external loading and transmitted the data to the reader and host computer via RF communication. The developed software automatically recorded the experimental data.

Fig. 7
Fig. 7

Schematic diagram of the structural strain monitoring tests. (This figure was created by Dr. Zhenwei Zhou using Microsoft PowerPoint 2024 (https://www.microsoft.com/microsoft-365/powerpoint).

In addition, a comprehensive evaluation of the actual measurement accuracy and application effects of the proposed sensing system was conducted by comparing it with traditional strain gauge and a Farsens wireless strain sensing system. Figure 8(a) shows the traditional strain gauge, which has a resistance of 1000 Ω and a sensitivity coefficient of 2.0 ± 1%. The Farsens system, implemented using the EVAL01-Rmeter-RM platform, performs strain monitoring by measuring changes in resistance. Since strain gauges with high resistance value and high sensitivity are advantageous for improving measurement accuracy, the TP-4-1000 semiconductor strain gauge was integrated with the EVAL01-Rmeter-RM, forming the Farsens wireless strain sensing system in Fig. 8(b). The Farsens system is designed to monitor physical quantities that induce changes in circuit resistance and is compatible with various resistive sensors. It operates within a frequency range of 860 MHz-960 MHz, with a read range of up to 5 m and a measurement accuracy of ± 1% within the specified precision range. The proposed wireless sensing system follows a similar design principle to the Farsens system, in which sensing elements are integrated with RFID tags for measurement. The sensing node also selects the TP-4-1000 semiconductor strain gauge, which is connected to the signal conditioning circuit of the sensing node, as shown in Fig. 8(c).

Fig. 8
Fig. 8

Sensors in the experiment: (a) the traditional strain gage; (b) Farsens syetem; (c) the proposed system.

The test utilized an aluminum plate with dimensions of 500 mm×60 mm×3 mm, an elastic modulus of 68.9 GPa, a Poisson’s ratio of 0.18, and a mass density of 1500 kg/m3. Monitoring points were positioned 100 mm from the fixed end to ensure accurate and reliable strain measurement. During experimental preparation, the specimen surface was carefully polished and cleaned with alcohol. Three sets of strain gauges were precisely bonded at adjacent parallel locations. Figures 9 and 10 depict the on-site experimental system. The RFID transmission module war positioned 1.2 m from the monitoring location to ensure stable communication performance. In the traditional monitoring approach, the strain gauge was directly connected to a dynamic–static signal testing and analysis system, and the measured results were used as reference values for structural strain, serving as a benchmark for comparison with the wireless measurements. Moreover, to ensure data integrity and facilitate analysis, reliable connections were established among the dynamic–static signal testing and analysis system, the RCRD001 ultra-high-frequency reader, and the computer platform, enabling real-time data acquisition and processing.

Fig. 9
Fig. 9

Details of the structural strain monitoring tests in the lab.

Fig. 10
Fig. 10

Strain monitoring and acquisition: (a) the monitoring locations of the sensors; (b) strain acquisition.

Weights of 100 g, 200 g, and 500 g were as loading masses in the test. Additionally, considering the residual stress induced after each bending cycle, the applied load was limited below the yield threshold to ensure immediate repeatability of the experiments. Otherwise, the cantilever plate would not fully recover to its initial state within a short time. The configurations of the four loading cases are summarized in Table 1. Case 1 involved stepwise loading increments of 1 N, reaching a maximum load of 30 N with a 30s interval between load steps, resulting in a total of 30 loading stages. Case 2 utilized stepwise loading increments of 5 N with a 60 s interval. Cases 3 and 4 involved random loading within the range of 0–50 N using discrete weights, with loading intervals of 15s and 5s, respectively. The accuracy and practical applicability of the proposed method were evaluated through comparative analysis.

Table 1 Experimental testing cases.

Results and discussions

Cases and 2 primarily differ in terms of load increment and loading interval. In Case 1, stepwise loading was applied with an increment of 1 N and a loading interval of 30 s. Figures 11 and 12 present the comparison results of the stepwise loading cases 1 and 2. Analysis of the collected data reveals strong agreement among the Farsens strain sensing system, the proposed system, and the strain reference values obtained from the dynamic-static signal testing and analysis system. These sensors exhibit consistent and rapid responses to strain variations, demonstrating high sensitivity and responsiveness. In contrast, Case 2 employed a larger load increment of 5 N with a longer interval of 60 s. The proposed wireless strain sensor maintained stable performance, accurately capturing strain variations and remaining consistent with the reference measurements. Despite the absolute error remained approximately constant, the relative error increased during the initial loading and final unloading stages due to the relatively small strain values. Overall, most monitoring errors of the proposed system in both cases were within a precision range of 5%. The discrepancy between theoretical error 0.443% and experimental errors is mainly due to practical factors, including energy fluctuations in wireless powering, RF link attenuation, environmental noise, and uncertainties in sensor installation and loading conditions. These findings further demonstrate that the proposed system exhibits superior strain monitoring performance compared to the Farsens sensor under stepwise loading conditions.

Fig. 11
Fig. 11

Comparison of the strain monitoring results from different sensors in case 1.

Fig. 12
Fig. 12

Comparison of the strain monitoring results from different sensors in case 2.

To rigorously and objectively evaluate the measurement performance of the proposed strain sensing system in comparison with the commercial Farsens system, it is insufficient to rely solely on qualitative comparisons of the measured signals. Therefore, quantitative evaluation indicators are introduced to systematically assess the deviation between the measured values and the actual strains. Four widely adopted statistical indicators are employed, including the mean absolute error (MAE), root mean square error (RMSE), mean absolute percentage error (MAPE), and coefficient of determination (R²). The corresponding formulations are presented as follows:

$$\left\{ \begin{gathered} {\text{MAE}} = \frac{1}{n}\sum\limits_{{n = 1}}^{n} {\left| {\varepsilon _{i} – \hat{\varepsilon }_{i} } \right|} \hfill \\ {\text{RMSE}} = \sqrt {\frac{1}{n}\sum\limits_{{n = 1}}^{n} {(\varepsilon _{i} – \hat{\varepsilon }_{i} )^{2} } } \hfill \\ {\text{MAPE}} = \frac{1}{n}\sum\limits_{{n = 1}}^{n} {\left| {\frac{{\varepsilon _{i} – \hat{\varepsilon }_{i} }}{{\varepsilon _{i} }}} \right| \times 100\% } \hfill \\ {\text{R}}^{2} = 1 – \frac{{\sum\nolimits_{{n = 1}}^{n} {(\varepsilon _{i} – \hat{\varepsilon }_{i} )^{2} } }}{{\sum\nolimits_{{n = 1}}^{n} {(\varepsilon _{i} – \bar{\varepsilon }_{i} )^{2} } }} \hfill \\ \end{gathered} \right.$$

(13)

where \(\varepsilon _{i}\) denotes the true strain value of the i-th sample, \(\hat{\varepsilon }_{i}\) represents the corresponding measured value, \(\bar{\varepsilon }_{i}\) is the mean value of the actual strain, and n is the total number of samples. Among them, a smaller MAE, RMSE, and MAPE, together with an R2 value closer to 1, indicates superior overall performance of the strain measurement system, implying a higher accuracy in capturing the actual variation of structural strain.

Figure 13 presents a comparative evaluation of the strain measurement performance between the Farsens system and the proposed system. In Case 1, the MAE, RMSE, and MAPE of the Farsens system are 10.72µε, 13.51µε, and 8.64%, respectively, whereas the proposed method achieves significantly lower values of 2.45µε, 3.43µε, and 2.88%. Similarly, in Case 2, the corresponding metrics for the Farsens system are 9.87µε, 12.21µε, and 7.95%, while the proposed method attains 2.10µε, 2.99µε, and 2.41%. These results demonstrate that the proposed method consistently achieves substantial reductions in all error metrics across different test cases, indicating a closer agreement with the reference values and a markedly improved measurement accuracy. Regarding fitting performance, the R2 for the Farsens system are 0.9986 and 0.9989, whereas those of the proposed method reach 0.99991 and 0.99994, respectively, approaching 1. This confirms that the proposed system provides superior agreement with the reference data and exhibits enhanced fitting capability. Thus, the proposed system consistently outperforms the Farsens system under stepwise loading conditions.

Fig. 13
Fig. 13

Comparison of strain measurement performance between the Farsens system and the proposed system under stepwise loading cases.

The performance of the proposed wireless system under complex strain variations was examined by applying random loads to the test plate. Figure 14 presents a comparison of strain measurements for random loading Cases 3 and 4. For Case 3, the loading interval was set to 15 s. The results indicate that both the Farsens system and the proposed system exhibit strong agreement with the reference strain values. Both sensing approaches respond rapidly to load changes and accurately capture dynamic strain in real time. In case 4, the loading interval was reduced to 5 s, resulting in more frequent and pronounced load fluctuations. Under these conditions, the proposed system continued to operate reliably, maintaining good agreement with the reference measurements. This observation further confirms its reliability and stability under highly dynamic strain conditions. Under both stepwise and random loading conditions, the Farsens system and the proposed system demonstrate high consistency with the reference strain values and exhibit prompt responses during both loading and unloading processes. Overall, the proposed system shows superior performance in strain measurement, particularly under stepwise loading conditions.

Fig. 14
Fig. 14

Comparison of the strain monitoring results from different sensors: (a) case 3; (b) case 4.

Source: www.nature.com